TRIPPLITE PDU3V20D354B
- Part Number: PDU3V20D354B
- Category: PDUs
- Manufacturer: Tripp Lite
- Quantity: 6
The PDU3V20D354B 8.6/12.6kW 3-Phase Vertical Power Distribution Unit(PDU) Outlet Strip is a required accessory option for Tripp Lite's PDU330AT6L21, PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other 3-phase auto-transfer switch(ATS) PDUs that specify compatibility with this model. It's ideal for high-density equipment racks in data centers and server rooms.
When used with 208V ATS models with a 35A input rating(such as PDU350AT6H50), the PDU3V20D354B supports up to 12.6kW total output with 20A maximum full balanced load per phase combination output bank(L1-L2, L2-L3, L3-L1). When used with 208V ATS PDU models with a 24A input rating(such as PDU330AT6L21, PDU330AT6L2130, PDU330AT6L1530 or PDU330AT6L15), it supports up to 8.6kW total output with 13.9A maximum balanced load per phase combination output bank.
The 48 C13 and 6 C19 single-phase outlets receive power from the the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations(L1-L2, L2-L3, L3-L1) throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers each. The 2.5-foot power cord with 8-position plug connects directly to the PDU's rear receptacle.
The PDU3V20D354B's rugged all-metal housing mounts in compatible racks in seconds with no tools needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack.
When used with 208V ATS models with a 35A input rating(such as PDU350AT6H50), the PDU3V20D354B supports up to 12.6kW total output with 20A maximum full balanced load per phase combination output bank(L1-L2, L2-L3, L3-L1). When used with 208V ATS PDU models with a 24A input rating(such as PDU330AT6L21, PDU330AT6L2130, PDU330AT6L1530 or PDU330AT6L15), it supports up to 8.6kW total output with 13.9A maximum balanced load per phase combination output bank.
The 48 C13 and 6 C19 single-phase outlets receive power from the the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations(L1-L2, L2-L3, L3-L1) throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers each. The 2.5-foot power cord with 8-position plug connects directly to the PDU's rear receptacle.
The PDU3V20D354B's rugged all-metal housing mounts in compatible racks in seconds with no tools needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack.
Technical Information
Output Receptacles: 6 x IEC 60320 C19Output Receptacles: 48 x IEC 60320 C13
Power Description
Input Voltage: 230 V ACOutput Voltage: 230 V AC
Power Rating: 12.60 kVA
Input Current: 35 A
Physical Characteristics
Form Factor: Vertical RackmountRack Height: 0U
Height: 70"
Width: 2.2"
Depth: 2.2"
Weight (Approximate): 9.26 lb
Miscellaneous
Green Compliant: YesGreen Compliance Certificate/Authority: RoHS